Stefan diffusion cell, studio

Description

Governing relation: NA = DP/(RTL) ln[1/(1−yA₁)]; yA₂ = 0, D = 10⁻⁵ m²/s, L = 80 mm. Assembly: Mount capillary in temperature-controlled bath. Align microscope with liquid meniscus and connect sweep-gas header. Measure meniscus retreat, temperature and composition before estimating D. Limits: D and interface composition are assumed.

Stefan-flow correction is included, but buoyancy, meniscus motion and bath control are not simulated. Recorded status: Research concept; hardware qualification not established. Collection README records 19 nominal scenes blocked by route issues; sine-bar has no cable routes. This inventory did not rerun route approval.

Where the triangles are

  1. STU08-001 Sixteen-strand protective braid37k · 3.4%
  2. STU08-002 Sixteen-strand protective braid37k · 3.4%
  3. ST-041 Header support mounting screw shank23k · 2.1%
  4. ST-044 Header support mounting screw shank23k · 2.1%
  5. ST-053 Microscope stand mounting screw shank23k · 2.1%
  6. ST-056 Microscope stand mounting screw shank23k · 2.1%
  7. STD-008 Bath and imaging controller captive cover fastener shank22k · 2.1%
  8. STD-012 Bath and imaging controller captive cover fastener shank22k · 2.1%

Materials

  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25

And 979 more.

Motion

One cycle of the study's saved operating simulation at the default control value: Steady vapor transport — coloured markers and guide lines travel over the assembly, driven by operation(model, x, progress) in operation-core.mjs for progress 0 to 1. The overlay is illustrative; the detailed parts are not rebuilt per frame. The study plays a cycle over 8 seconds; 24 frames sample it, so closely spaced markers can appear to flicker or step.

Specification

CategoryInstruments and research devices / Engineering test rigs
KindMass transfer
CollectionTwenty engineering classes
RepositoryMACHINES
Version keptCatalogued build, 2026-10-03
Confidencehigh
Runtimethreejs
Bounding box0.34 × 0.30 × 0.26 m
Draw calls989
Codesources/apexagi/studies/engineering-20-20260930/models/09-stefan-tube.mjs + 1 files
Built and measured2026-11-24, 2.5 s build, three.js r185

Effects

  • emissive 3
  • transparent 10
  • clearcoat 30

More engineering test rigs See all 13