Double-sided guarded hot plate, studio

Description

Governing relation: λ = QL/(2AΔT); A = π(0.050 m)², L = 0.020 m, ΔT = 30 K. Assembly: Install lower cold plate, lower sample and guarded meter assembly. Fit upper sample, upper cold plate and force-spreading platen. Connect independent guard and meter control channels; establish steady state before measuring. Limits: No measured temperatures or heat losses.

Contact resistance, edge leakage, heater calibration and uncertainty remain open. Recorded status: Research concept; hardware qualification not established. Collection README records 19 nominal scenes blocked by route issues; sine-bar has no cable routes. This inventory did not rerun route approval.

Where the triangles are

  1. GHU08-001 Sixteen-strand protective braid37k · 2.5%
  2. GHU08-002 Sixteen-strand protective braid37k · 2.5%
  3. GH-024 Tie rod anchor shank29k · 2%
  4. GH-056 Tie rod anchor shank29k · 2%
  5. GH-088 Tie rod anchor shank29k · 2%
  6. GH-120 Tie rod anchor shank29k · 2%
  7. GHD-008 Meter and guard controller captive cover fastener shank22k · 1.5%
  8. GHD-012 Meter and guard controller captive cover fastener shank22k · 1.5%

Materials

  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25

And 1259 more.

Motion

One cycle of the study's saved operating simulation at the default control value: Steady heat transfer — coloured markers and guide lines travel over the assembly, driven by operation(model, x, progress) in operation-core.mjs for progress 0 to 1. The overlay is illustrative; the detailed parts are not rebuilt per frame. The study plays a cycle over 8 seconds; 24 frames sample it, so closely spaced markers can appear to flicker or step.

Specification

CategoryInstruments and research devices / Measurement and metrology
KindThermal metrology
CollectionTwenty engineering classes
RepositoryMACHINES
Version keptCatalogued build, 2026-10-03
Confidencehigh
Runtimethreejs
Bounding box0.31 × 0.23 × 0.28 m
Draw calls1,269
Codesources/apexagi/studies/engineering-20-20260930/models/07-guarded-hot-plate.mjs + 1 files
Built and measured2026-11-24, 1.4 s build, three.js r185

Effects

  • emissive 3
  • clearcoat 23

More measurement and metrology See all 10