Guarded Faraday charge collector, studio

Description

Governing relation: Particle rate = I/(ze); Vout = −IRf; z = 1, Rf = 10 MΩ, e = 1.602176634×10⁻¹⁹ C. Assembly: Mount collector on insulating standoffs inside guard shield. Install aperture and suppression electrode with clear isolation gaps. Connect guarded feedthrough to calibrated current amplifier. Limits: The model contains no particle source.

Collection efficiency, suppression voltage, amplifier noise and vacuum compatibility need measurement. Recorded status: Research concept; hardware qualification not established. Collection README records 19 nominal scenes blocked by route issues; sine-bar has no cable routes. This inventory did not rerun route approval.

Where the triangles are

  1. FCU08-001 Sixteen-strand protective braid37k · 2.6%
  2. FCU08-002 Sixteen-strand protective braid37k · 2.6%
  3. FC-024 Chamber cradle mounting screw shank23k · 1.6%
  4. FC-027 Chamber cradle mounting screw shank23k · 1.6%
  5. FC-033 Chamber cradle mounting screw shank23k · 1.6%
  6. FC-036 Chamber cradle mounting screw shank23k · 1.6%
  7. FC-043 Chamber cradle mounting screw shank23k · 1.6%
  8. FC-046 Chamber cradle mounting screw shank23k · 1.6%

Materials

  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25

And 1026 more.

Motion

One cycle of the study's saved operating simulation at the default control value: Charge collection — coloured markers and guide lines travel over the assembly, driven by operation(model, x, progress) in operation-core.mjs for progress 0 to 1. The overlay is illustrative; the detailed parts are not rebuilt per frame. The study plays a cycle over 8 seconds; 24 frames sample it, so closely spaced markers can appear to flicker or step.

Specification

CategoryInstruments and research devices / Measurement and metrology
KindCharge measurement
CollectionTwenty engineering classes
RepositoryMACHINES
Version keptCatalogued build, 2026-10-03
Confidencehigh
Runtimethreejs
Bounding box0.30 × 0.20 × 0.29 m
Draw calls1,036
Codesources/apexagi/studies/engineering-20-20260930/models/15-faraday-cup.mjs + 1 files
Built and measured2026-11-24, 1.7 s build, three.js r185

Effects

  • emissive 3
  • clearcoat 27

More measurement and metrology See all 10