Scanning Fabry–Pérot cavity, studio

Description

Governing relation: FSR = c/(2L); finesse ≈ π√R/(1−R); linewidth ≈ FSR/finesse, R = 0.95. Assembly: Mount fixed mirror and piezo-driven mirror on parallel translation rails. Align cavity with mode-matched source and detector. Calibrate scan linearity against a known frequency interval. Limits: Alignment, diffraction, coating loss, transverse modes and piezo hysteresis are excluded.

This is not the confocal c/(4L) mode-spacing convention. Recorded status: Research concept; hardware qualification not established. Collection README records 19 nominal scenes blocked by route issues; sine-bar has no cable routes. This inventory did not rerun route approval.

Where the triangles are

  1. FPU08-001 Sixteen-strand protective braid37k · 2.7%
  2. FPU08-002 Sixteen-strand protective braid37k · 2.7%
  3. FP-001 Machined datum bed25k · 1.8%
  4. FP-027 Mirror pedestal -1 mounting screw shank23k · 1.6%
  5. FP-030 Mirror pedestal -1 mounting screw shank23k · 1.6%
  6. FP-121 Mirror pedestal 1 mounting screw shank23k · 1.6%
  7. FP-124 Mirror pedestal 1 mounting screw shank23k · 1.6%
  8. FP-228 Optical end support mounting screw shank23k · 1.6%

Materials

  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • navyMeshPhysical · metal 0.72 · rough 0.37
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25

And 1329 more.

Motion

One cycle of the study's saved operating simulation at the default control value: Cavity transmission scan — coloured markers and guide lines travel over the assembly, driven by operation(model, x, progress) in operation-core.mjs for progress 0 to 1. The overlay is illustrative; the detailed parts are not rebuilt per frame. The study plays a cycle over 8 seconds; 24 frames sample it, so closely spaced markers can appear to flicker or step.

Specification

CategoryInstruments and research devices / Measurement and metrology
KindOptical spectroscopy
CollectionTwenty engineering classes
RepositoryMACHINES
Version keptCatalogued build, 2026-10-03
Confidencehigh
Runtimethreejs
Bounding box0.46 × 0.17 × 0.24 m
Draw calls1,339
Codesources/apexagi/studies/engineering-20-20260930/models/17-fabry-perot.mjs + 1 files
Built and measured2026-11-24, 2.0 s build, three.js r185

Effects

  • emissive 4
  • transparent 7
  • clearcoat 35

More measurement and metrology See all 10