McLeod compression gauge, studio

Description

Governing relation: p = ρgh·v/(V−v); v = πr²h, V = 50 cm³, r = 0.5 mm. Assembly: Mount sealed bulb, capillaries and reservoir as a qualified glass assembly. Establish trapped-volume and capillary calibration. Pressure interpretation requires noncondensing gas and controlled temperature. Limits: Conceptual sealed instrument only.

Condensable vapor, capillary depression, volume calibration and hazardous-material handling are unresolved. Recorded status: Research concept; hardware qualification not established. Collection README records 19 nominal scenes blocked by route issues; sine-bar has no cable routes. This inventory did not rerun route approval.

Where the triangles are

  1. MGU08-001 Sixteen-strand protective braid37k · 3.4%
  2. MGD-091 Scale fixing screw shank23k · 2.1%
  3. MGD-095 Scale fixing screw shank23k · 2.1%
  4. MGD-008 Pressure logging module captive cover fastener shank22k · 2%
  5. MGD-012 Pressure logging module captive cover fastener shank22k · 2%
  6. MGD-016 Pressure logging module captive cover fastener shank22k · 2%
  7. MGD-020 Pressure logging module captive cover fastener shank22k · 2%
  8. MG-026 Compression bulb outer glass21k · 1.9%

Materials

  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • steelMeshPhysical · metal 0.94 · rough 0.25
  • glassMeshPhysical · metal 0.05 · rough 0.1
  • rubberMeshPhysical · metal 0.02 · rough 0.76
  • rubberMeshPhysical · metal 0.02 · rough 0.76

And 900 more.

Motion

One cycle of the study's saved operating simulation at the default control value: Isothermal compression — coloured markers and guide lines travel over the assembly, driven by operation(model, x, progress) in operation-core.mjs for progress 0 to 1. The overlay is illustrative; the detailed parts are not rebuilt per frame. The study plays a cycle over 8 seconds; 24 frames sample it, so closely spaced markers can appear to flicker or step.

Specification

CategoryInstruments and research devices / Measurement and metrology
KindVacuum metrology
CollectionTwenty engineering classes
RepositoryMACHINES
Version keptCatalogued build, 2026-10-03
Confidencehigh
Runtimethreejs
Bounding box0.30 × 0.49 × 0.24 m
Draw calls910
Codesources/apexagi/studies/engineering-20-20260930/models/11-mcleod-gauge.mjs + 1 files
Built and measured2026-11-24, 1.3 s build, three.js r185

Effects

  • emissive 3
  • transparent 10
  • clearcoat 30

More measurement and metrology See all 10